Chemical Compatibility Guide

Published chemical-resistance data for the ERECTA SWITCH wetted materials, at 20 °C, 60 °C and 90 °C. Every rating is the material manufacturer's own, cited with the revision date of the document it came from — look up your chemistry and judge it against your own process conditions.

loading… Download PDF chart
NF means NOT FOUND — and it is not a pass. NR means NOT RECOMMENDED — the maker tested it and it fails. The two are deliberately different badges: one is silence, the other is a warning, and they must never be confused. NF means that manufacturer published nothing for that chemical at that temperature. Three of the five manufacturers stop below 90 °C, so blanks are common in the 90 °C columns.
Ratings also move with heat, and they move one way: of the 176 grade changes between 20 °C and 60 °C in this data, all 176 are downgrades. Never read a 20 °C rating as a hot-service rating.
ASuitableBSuitable, limitedCIntermittent onlyNRNot recommendedNFNot found ‡the maker publishes more than one concentration band for this chemical and they do not agree; the worst is shown. Use the online lookup with your actual concentration.
*Material maker's rating. The resin, metal or elastomer producer's own published resistance data. It describes the MATERIAL, not an assembled product.**Component maker's system rating. A named manufacturer's published service limit for a FINISHED ASSEMBLY in this chemical — it already accounts for seals, joints and duty. It answers a different question from a material maker's rating, and the two can differ in EITHER direction. Compare them; never average them, and never assume one is the cautious one.
ChemicalPVDF / KynarPolypropyleneAcetal (POM)Titanium Gr 4Viton (FKM)EPDM
Arkema Kynar PVDF Chemical Resistance Chart * rev 2023-03-07
NIBCO INC. ** rev 2009-09
Braskem S.A. * rev 2005-12
NIBCO INC. ** rev 2009-09
Celanese * rev 2016-10
BASF rev 2000-10
TIMET * rev 1998-01Parker Hannifin * rev 2018-11
NIBCO INC. ** rev 2009-09
no temp. basis
Parker Hannifin * rev 2018-11
NIBCO INC. ** rev 2009-09
no temp. basis
20 / 60 / 90 °C20 / 60 / 90 °C20 / 60 / 90 °C20 / 60 / 90 °Cno temp. basisno temp. basis
Loading the chart…