ERECTA SWITCH® by Compac Engineering
Components · Wiring Enclosures

ERECTA SWITCH® Wiring Enclosures

Modular receptacle system for ERECTA SWITCH switch-to-cable wiring connections. Sealed plastic enclosures protect wiring from moisture, dust, and chemical splash. Round threaded and hex body styles with NPT conduit bore. Stack mid sections and blanks to build multi-switch wiring enclosures for extended stem configurations. Available in Polypropylene, Acetal, and PVDF Kynar.

In stock · Made in Paradise, CA
PP · Acetal · PVDF Kynar
RoHS Compliant throughout
No minimum order

Select an Enclosure

10-700-RT Round Threaded Receptacle
10-700-RT
Round Threaded Receptacle

1¼″ round threaded receptacle with NPT conduit bore. Sealed wiring enclosure for single-switch installations. Stackable.

PP Acetal Kynar
10-700-RB Receptacle Blank
10-700-RB
Receptacle Blank

1¼″ NPS blank receptacle cap. Seals unused switch positions in multi-switch wiring enclosure stacks. Future expansion ready.

PP Acetal Kynar
10-700-RM Hex Receptacle
10-700-RM
Hex Receptacle

Hex body wiring enclosure with wrench flats. Accepts one switch plus tube passage for the 10-715 precision nipple.

PP Acetal Kynar
10-700-RS Hex Receptacle C'Bore + O-Ring
10-700-RS
Hex Receptacle, C'Bore + O-Ring

1¼″ NPT hex receptacle with counterbore and O-ring seal. Snap-on cap with conduit knockout. 100 PSI rated.

PP Acetal Kynar
10-701-RS Round Receptacle C'Bore + O-Ring
10-701-RS
Round Receptacle, C'Bore + O-Ring

Smooth round-body receptacle with panel/press-fit mount. Counterbore + O-ring seal. Snap-on cap with conduit knockout. 100 PSI rated.

PP Acetal Kynar
10-700-MS Mid Section
10-700-MS
Receptacle Mid Section

Adds one switch position to the wiring enclosure stack. ¼″ NPT side-entry conduit port. Stack multiple for multi-level assemblies.

PP Acetal Kynar
10-700-RX Receptacle
10-700-RX
Receptacle

General-purpose wiring enclosure receptacle. 1¼″ NPS thread. Stackable with mid sections for multi-switch assemblies.

PP Acetal Kynar
10-701-HB Relay Housing Blind
10-701-HB
Relay Housing Blind

Blind relay housing for unused positions in multi-switch relay assemblies. Seals the housing stack.

10-701-HS Relay Housing CB+OR
10-701-HS
Relay Housing, C'Bore + O-Ring

Relay housing with counterbore and O-ring seal. Pressure-rated for sealed relay switch installations.

10-701-HT Relay Housing CB+OR NPS
10-701-HT
Relay Housing, C'Bore + O-Ring NPS

Relay housing with counterbore, O-ring seal, and ¼″ NPS conduit entry. Pressure-rated with cable routing.

10-701-HX Relay Housing
10-701-HX
Relay Housing

General-purpose relay housing for Series 10 level switch relay assemblies. Stackable design.

10-701-RB Receptacle Blank
10-701-RB
Receptacle Blank

Blank receptacle cap for unused positions in snap-in wiring enclosure assemblies. Future expansion ready.

PP Acetal Kynar
10-701-RM Hex Receptacle
10-701-RM
Hex Receptacle

Hex-body wiring enclosure with snap-in design for panel-mount installations. Wrench flats for secure installation.

PP Acetal Kynar
10-701-RT Round Receptacle CB+OR
10-701-RT
Round Receptacle, C'Bore + O-Ring

Round-body receptacle with counterbore and O-ring seal. Snap-on cap with conduit knockout.

PP Acetal Kynar
10-701-RX Receptacle
10-701-RX
Receptacle

General-purpose snap-in wiring enclosure receptacle. Stackable with mid sections for multi-switch assemblies.

PP Acetal Kynar
10-701-SM Mid Section
10-701-SM
Receptacle Mid Section

Extends the snap-in wiring enclosure stack with an additional switch position. 10-pack.

PP Acetal Kynar
10-702-CM Receptacle Top
10-702-CM
Receptacle Top

Top cap and screw for pop-in wiring enclosure assemblies. Seals the top of the receptacle stack. 10-pack.

PP Acetal Kynar
10-702-RB Receptacle Blank
10-702-RB
Receptacle Blank

Blank receptacle cap for unused positions in pop-in wiring enclosure assemblies. 10-pack.

PP Acetal Kynar
10-702-RM Hex Receptacle
10-702-RM
Hex Receptacle

Hex-body pop-in wiring enclosure. Snap-in design for 1-9/16″ panel mounting. 10-pack.

PP Acetal Kynar
10-702-RS Round Receptacle
10-702-RS
Round Receptacle

Round-body pop-in receptacle with O-ring seal for panel-mount installations. 10-pack.

PP Acetal Kynar
10-702-RT Round Receptacle NPS
10-702-RT
Round Receptacle NPS

Round-body pop-in receptacle with O-ring seal and NPS conduit entry. 10-pack.

PP Acetal Kynar
10-702-RX Receptacle
10-702-RX
Receptacle

General-purpose pop-in wiring enclosure receptacle for panel-mount installations. 10-pack.

PP Acetal Kynar
10-703-CM Receptacle Top
10-703-CM
Receptacle Top

Top cap and screw for wiring enclosure assemblies. Seals the top of the receptacle stack. 10-pack.

PP Acetal Kynar
10-703-RM Hex Receptacle
10-703-RM
Hex Receptacle

Hex-body wiring enclosure with 1/8″ conduit entry and bolt mounting. 10-pack.

PP Acetal Kynar
10-704-RM Hex Receptacle
10-704-RM
Hex Receptacle

Hex-body wiring enclosure with clamp bracket and NPT conduit entry. 10-pack.

PP Acetal Kynar
10-705-RM Hex Receptacle
10-705-RM
Hex Receptacle

Hex-body wiring enclosure with hex bracket and NPT conduit entry. 10-pack.

PP Acetal Kynar

Chemical Compatibility & Selection Guide

Polypropylene (PP)

Excellent resistance to water, soaps, light acids, and mild alkalis. The standard choice for water treatment, food processing, and general industrial applications. Most economical option.

Acetal (AC)

Engineered for hydrocarbons — gasoline, diesel, hydraulic oil, and lubricants. Not recommended for strong acids or oxidizing agents. Preferred for fuel system and mobile equipment applications.

PVDF Kynar (KR)

Maximum chemical resistance for harsh environments. Handles strong acids, caustics, chlorinated solvents, and high-purity chemical service. Specified for semiconductor, electroplating, and chemical processing.

Frequently Asked Questions

Common Questions About This Product

What liquid chemistries is the ERECTA SWITCH component compatible with?

Choose the material to match the media: Polypropylene (PP) for general aqueous, acids, and bases; Acetal (AC/Delrin) for solvents, fuels, and hydrocarbons; Kynar PVDF (KR) for aggressive or harsh chemicals. Every ERECTA SWITCH model is offered in all three materials.

What factors should I consider when choosing the ERECTA SWITCH component?

Consider media chemistry (pick PP, AC, or KR), liquid specific gravity, operating temperature and pressure, mounting style, number of switch points, and electrical contact rating. Compac will spec it from your application — request a free evaluation sample.

What makes ERECTA SWITCH different from other level switches?

It is the only fully modular, off-the-shelf liquid level switch system: switch, float, connector, fitting, and nipple are independently field-replaceable and stocked. OEMs configure exactly what they need with no minimums and short lead times. Made in Paradise, California; RoHS compliant.

Can I order individual ERECTA SWITCH replacement components?

Yes. The ERECTA SWITCH component is available as an individual, stocked part — no need to replace the entire switch assembly. ERECTA SWITCH is a fully modular system: switch, float, connector, fitting, spacer, and nipple are all orderable separately with no minimums. This reduces repair cost and downtime for OEM field service.

Are ERECTA SWITCH components interchangeable across models?

Yes — modularity is the core of the ERECTA SWITCH system. The ERECTA SWITCH component is designed to work across multiple Series 10 configurations. Floats, connectors, spacers, and fittings share standard interfaces, so one stocked component serves many switch assemblies. Check the model number to confirm compatibility.

How do I identify which ERECTA SWITCH component I need?

Each component has a unique model number (e.g., ERECTA SWITCH component) that identifies its type, material, and function within the assembly. Contact Compac with your switch model number and the part you need to replace — or request a free evaluation sample to confirm fit before ordering production quantities.