ERECTA SWITCH® by Compac Engineering
◆ Series 10 — Subcategory 3

One Level Extended Stem
Float Level Switch Sets

Single-level switching at any depth from 1″ to 70″. Choose your mounting style, connector orientation, and material — each set includes everything except the 10-715 Precision Nipple, which determines your switching depth. Available in Polypropylene, Acetal, and PVDF Kynar for broad chemical compatibility.

16
Configurations
1–70″
Stem Lengths
3
Materials
4
Mounting Styles
10-715 Precision Nipple Required: All extended stem sets ship without the 10-715 Precision Nipple. You need one nipple per level — it determines the exact switching depth. The 10-715 is available in lengths from 1″ to 70″ in 1″ increments. Order 10-715 Precision Nipples →

Choose Your Configuration

Each model below is available in PP, AC, and KR materials. Click any model to select material and packaging options.

◆ Technical Specifications

Specifications & Ratings

All models use the 10-782 magnetic reed switch as the sensing element. Common ratings apply across all 16 configurations.

Switch Type

SPST Magnetic Reed
Standex/OKI ORD229 hermetically sealed

Electrical Rating

70VA / 50W resistive
AC 0.5A / DC 0.7A · Max 300VAC / 350VDC · Inductive loads such as solenoid and relay coils require external arc suppression; above the rating, isolate the load with a Series 50 relay.

Pressure / Temperature

100 PSI / 90°C
Hollow float @ 20°C · Derate to 0 PSI @ 90°C

Specific Gravity

0.8 Minimum
Clear liquid required

PP — Polypropylene

Water, Soaps, Light Acids
Gray & black construction

AC — Acetal

Hydrocarbons, Diesel, Oils
Red construction

KR — PVDF Kynar

Harsh Chemicals, Acids, Caustics
Natural construction

Certifications

RoHS Compliant
UL component recognition (KOFU switch)

Model-by-Model Comparison

Model Mounting Thread Connector Relay Housing Adapter Slosh Shield Materials
10-101 1-1/4″ Vertical NPT Straight — — — PP, AC, KR
10-101-SS 1-1/4″ Vertical NPT Straight — — ✓ PP, AC, KR
10-102 1-1/4″ Vertical NPT Angle — — — PP, AC, KR
10-102-SS 1-1/4″ Vertical NPT Angle — — ✓ PP, AC, KR
10-103 1-1/4″ Vertical NPT Straight ✓ — — PP, AC, KR
10-103-SS 1-1/4″ Vertical NPT Straight ✓ — ✓ PP, AC, KR
10-104 1-1/4″ Vertical NPT Angle ✓ — — PP, AC, KR
10-104-SS 1-1/4″ Vertical NPT Angle ✓ — ✓ PP, AC, KR
10-105 1-1/4″ Vertical NPT Straight ✓ Sealed Adapter — PP, AC, KR
10-105-SS 1-1/4″ Vertical NPT Straight ✓ Sealed Adapter ✓ PP, AC, KR
10-106 2″ Vertical NPT Straight ✓ Sealed Adapter — PP, AC, KR
10-106-SS 2″ Vertical NPT Straight ✓ Sealed Adapter ✓ PP, AC, KR
10-107 Flange — Straight ✓ Flange Nut + Sealed — PP, AC, KR
10-107-SS Flange — Straight ✓ Flange Nut + Sealed ✓ PP, AC, KR
10-108 Pop-In — Straight — Receptacle — PP, AC, KR
10-108-SS Pop-In — Straight — Receptacle ✓ PP, AC, KR

All models: SPST magnetic reed switch (Standex/OKI ORD229) · 70VA/50W · 100 PSI max @ 20°C · 90°C max · 0.8 SG min · Stem lengths 1″–70″ in 1″ increments · 10-715 Precision Nipple sold separately · Installation: outside → in (no internal tank access required) · RoHS Compliant

◆ Application Examples

OEM Application Scenarios

Real-world examples of how design engineers specify one-level extended stem sets. Each scenario identifies the mounting style, material, and model best suited to the application.

🏭

Cooling Tower Basin — Low Water Cutoff

Polypropylene · 1-1/4″ NPT Mount

An HVAC chiller OEM needs a low-water cutoff in their cooling tower basin. The tank lid is drilled and tapped with a 1-1/4″ NPT bung. Water chemistry is treated municipal water with mild corrosion inhibitors. The switch signals a PLC to shut down the compressor if water drops below the minimum circulation level. No relay housing needed — the PLC handles the load.

10-101-PP 10-101-SS-PP
⛽

Diesel Generator Fuel Tank — Low Level Alarm

Acetal · 1-1/4″ NPT Mount

A standby generator manufacturer needs a low-fuel alarm in their day tank. Diesel fuel requires Acetal construction for chemical compatibility. The angle connector routes the lead wire away from the tank wall in a tight engine compartment. The switch activates a warning lamp and audible alarm on the generator control panel. Relay housing protects the connection in an outdoor enclosure.

10-104-AC 10-102-AC
⚗️

Acid Dosing System — Replenishment Trigger

PVDF Kynar · 1-1/4″ NPT Mount

A water treatment equipment builder needs a level switch in a sulfuric acid bulk storage tank to trigger the replenishment pump. PVDF Kynar resists the acid chemistry. The sealed adapter on the 10-105 provides redundant O-ring moisture protection critical in corrosive vapor environments. The relay housing accepts an optional solid state relay for direct pump control.

10-105-KR 10-105-SS-KR
🍽️

Soap Dispensing System — Refill Level Detection

Polypropylene · 2″ NPT Mount

A commercial warewash OEM needs level detection in their bulk soap reservoir. The 2″ NPT opening is standard on their molded polypropylene tank. Polypropylene construction is compatible with soap solutions and mild alkaline cleaners. The 10-106 set's sealed adapter prevents soap residue from wicking up through the threaded connection. The relay housing allows field-installation of a solid state relay to control the soap metering pump.

10-106-PP 10-106-SS-PP
🔧

Polyethylene Tank — No-Thread Installation

Polypropylene · Flange Mount

A tank fabricator building custom polyethylene sumps needs level sensing without drilling and tapping threads. The 10-107 flange mount uses a hole-saw cut and flange nut — no threads required. This is common on rotomolded tanks where wall thickness varies and tapped threads may not hold. The sealed flange nut provides a watertight connection from outside the tank with no internal access required.

10-107-PP 10-107-SS-PP
🏗️

Injection Molding Chiller — Quick-Install Level Sensing

Polypropylene · Pop-In Mount

A plastics machinery OEM needs level sensing in their mold temperature controller reservoir but wants tool-free installation on the production line. The 10-108 pop-in mount snaps into a hole-saw cut — no threading, no flange nut, no tools. The wiring receptacle on top accepts a mating plug for quick connect/disconnect during machine assembly. Ideal for high-volume OEM production where assembly labor cost matters.

10-108-PP 10-108-SS-PP
🌊

Agitated Process Tank — Slosh-Resistant Level Control

Any Material · Slosh Shield Variants

Any tank with mechanical agitation, recirculation jets, or rapid fill/drain cycles creates turbulence that can cause false switch actuations. The SS (Slosh Shield) variants add a baffle around the float that dampens wave action and prevents nuisance trips. Choose the SS version of any base model when the liquid surface is not calm — mixing tanks, plating baths with air agitation, or tanks with side-entry return lines.

10-101-SS 10-103-SS 10-105-SS 10-107-SS
⚡

Electroplating Bath — Chemical-Resistant Level Monitoring

PVDF Kynar · Flange or Pop-In Mount

An electroplating equipment manufacturer needs level monitoring across multiple chemical baths — acid copper, nickel sulfamate, and chromic acid. PVDF Kynar handles the full range of plating chemistries. Flange mount (10-107-KR) works on custom-fabricated polypropylene tanks; pop-in mount (10-108-KR) works on standard polyethylene drum liners. Both install from outside the tank — no worker exposure to bath chemistry during installation.

10-107-KR 10-108-KR
◆ Technical Resources

Series 10 Technical Documents

Download detailed technical literature for the Series 10 product family. All extended stem sets use the 10-782 as their primary switching element.

Frequently Asked Questions

Common Questions About This Product

What is the difference between a float level switch and a liquid level sensor?

A float level switch like the Series 10 level switch is a point-level device: a float rides the liquid and actuates a magnetic reed switch at a set height, giving a simple on/off signal — no power, no firmware, no calibration. "Sensors" usually means continuous measurement (ultrasonic, radar, capacitive). ERECTA SWITCH targets reliable discrete-point control.

What factors should I consider when choosing the Series 10 level switch?

Consider media chemistry (pick PP, AC, or KR), liquid specific gravity, operating temperature and pressure, mounting style, number of switch points, and electrical contact rating. Compac will spec it from your application — request a free evaluation sample.

What liquid chemistries is the Series 10 level switch compatible with?

Choose the material to match the media: Polypropylene (PP) for general aqueous, acids, and bases; Acetal (AC/Delrin) for solvents, fuels, and hydrocarbons; Kynar PVDF (KR) for aggressive or harsh chemicals. Most ERECTA SWITCH models are offered in all three materials; some are material-specific, so check the product page for the model you need.

What mounting options are available for the Series 10 level switch?

ERECTA SWITCH offers vertical top-mount, bulkhead, and extended-stem configurations, plus side-mounted single-point models. The mount style is part of the model number — select the configuration that matches your tank geometry.

How is the actuation level set on the Series 10 level switch, and how accurate is it?

Point detection is repeatable and mechanical. The trip height on the Series 10 level switch is set by the 10-715 Precision Nipple, ordered separately in 1-inch increments (1″–70″), so you place the switch point exactly where the application needs it.

What pressure and temperature can the Series 10 level switch handle?

It depends on the series, and the derate matters more than the headline. Series 10 is rated 100 PSI, Series 15 50 PSI and Series 20 20 PSI — each at 20°C, each derating to zero at 90°C, so a hot line has no pressure allowance left. Series 20 sits lowest by design: its float sections are thin-walled, and sustained pressure can crush them. Temperature follows the material — on Series 10, PP: 180°F, AC: 200°F, KR: 280°F.

Can one Series 10 level switch switch control both a high and a low level?

A single switch detects one point. For high-plus-low detection (or more), use a multi-level extended-stem set that places multiple reed points on one stem, giving you independent high and low signals from a single mounting hole.

How do I wire the Series 10 level switch to a pump or alarm?

The Series 10 level switch uses a magnetic reed switch wired in series with your relay or controller. Contact rating is 70 VA / 50 W resistive (UL File E70063). The switch ships with lead wires — connect directly to your control circuit.

Does the Series 10 level switch need calibration?

No. The Series 10 level switch is a mechanical float actuating a sealed reed switch — there is nothing to calibrate or power. This is a reliability advantage over electronic sensors that can drift over time.

How do I maintain the Series 10 level switch, and what if it stops working?

Inspect that the float moves freely (check for debris or scaling), then test reed continuity with a multimeter. Because ERECTA SWITCH is modular, you replace only the individual component — switch, float, connector, or fitting — instead of the whole assembly.

Is the Series 10 level switch safe for flammable or hazardous-area liquids?

Standard ERECTA SWITCH models are not rated for hazardous (Class I / Div) areas. For flammable-service applications, contact Compac engineering to discuss your requirements and available options.

What are the typical applications for the Series 10 level switch?

The Series 10 level switch is used for pump start/stop control, high-level overflow protection, low-level dry-run protection, and tank or reservoir level alarms in OEM equipment. The modular ERECTA SWITCH system is built into laundry, HVAC, water-treatment, hydraulic, and chemical-handling machinery.

What makes ERECTA SWITCH different from other switches?

It is the only fully modular, off-the-shelf liquid level switch system: switch, float, connector, fitting, and nipple are independently field-replaceable and stocked. OEMs configure exactly what they need with no minimums and short lead times. Made in Paradise, California; RoHS compliant.

Not Sure Which Configuration?

Tell us your tank geometry, liquid chemistry, and switching depth — we'll recommend the right extended stem set for your application.