ERECTA SWITCH® by Compac Engineering
Since 1964 · Engineered and manufactured in Paradise, California 1-800-828-9044 · [email protected]
10-787 Polypropylene 1-Pack Side Mount · Series 10

10-787-PP Side Mounted Level Switch with Bulkhead Adapter (Polypropylene)

1/4" NPT side mount with 10-702-BH bulkhead — industrial-standard tank thread.

In Stock — Ships Wednesdays In stock · Ships from Paradise, California
As low as

Call 1-800-828-9044 for pricing.

$19.50/unit at volume
1-9$25.75
10-29$23.15
30-99$21.85
100+$19.50
Also Available

Product Description

The 10-787-PP is a side-mounted level switch configured for tanks with a 1/4" NPT side-wall bung. A 10-702-BH polypropylene bulkhead fitting converts the base 10-785-PP's 1/8" NPT mount to 1/4" NPT, matching the most common side-wall thread in industrial tank fabrication. The unicellular split-float clamps the horizontally oriented 10-782-PP stem and travels in a vertical slot as liquid rises and falls — field-reversible NO/NC via float orientation. Polypropylene wetted construction handles water, mild acids, caustics, detergents, and most aqueous solutions to 180°F (82°C) at 100 PSI (6.9 bar). Ships with 1/4" jam nut and 24" pigtail leads.

Key Features

Engineered specifications and field-service advantages — not marketing language.

1/4" NPT side-wall mount via 10-702-BH bulkhead

Matches standard industrial tank-wall threading without custom fabrication or thread adapters specified on a separate BOM line.

Unicellular split-float

Clamps the 10-782 stem; magnet orientation selects open-on-rise or close-on-rise at installation.

Sealed 10-782-PP reed switch

Hermetically sealed Standex/OKI ORD229 reed contacts rated 70 VA / 50 W resistive — max 0.5A AC / 0.7A DC, 300 VAC / 350 VDC (UL File E70063).

Polypropylene wetted parts

Compatible with water, mild acids/caustics, detergents, plating rinses, and aqueous process fluids.

ERECTA SWITCH modularity

The 10-702-BH bulkhead, split float, and stem are individually stocked — service without custom manufacturing.

Applications

Specific installation scenarios that match the 10-787-PP configuration.

Specifications

Model10-787-PP
Wetted materialPolypropylene
Chemical compatibilitywater, mild acids, caustics, detergents, and most aqueous solutions
Float operationHorizontal (split float)
Mount thread1/4" NPT via 10-702-BH bulkhead
Max temperature180°F (82°C) continuous
Max pressure100 PSI (6.9 bar)
Electrical rating70 VA / 50 W resistive — max 0.5A AC / 0.7A DC, 300 VAC / 350 VDC
Inductive loadsRequire external arc suppression — solenoid and relay coils. Above the rating, isolate the load with a Series 50 relay.
Lead length24" standard (72" available — contact factory)
Switch elementHermetically sealed reed (10-782-PP)
Pack configuration1-Pack
Country of manufactureParadise, California, USA

Not sure which configuration is right?

Compac application engineers help specify the correct level switch for your tank geometry, fluid chemistry, and operating environment — no obligation, no upsell.

Specifications

SpecificationValue
TypeSide mount level switch, split float with bulkhead adapter
MaterialPolypropylene (PP)
Thread1/4" NPT (10-702-BH adapter on the 10-785 1/8" NPT mount)
Switch Element10-782 magnetic reed switch
Contact ActionNO/NC field-reversible — orient the float magnet up for open-on-rise, down for close-on-rise. One SKU, two electrical configurations.
Contact Rating70 VA, 50W resistive · UL File E70063
Inductive LoadsRequire external arc suppression — solenoid and relay coils. Above the rating, isolate the load with a Series 50 relay.
Supplied With1/4" jam nut, 24″ pigtail leads
ComplianceRoHS
Pressure Rating100 PSI @ 20°C; derate to zero @ 90°C
Max TemperaturePP: 180°F / AC: 200°F / KR: 280°F
Frequently Asked Questions

Common Questions About This Product

What is the difference between a float level switch and a liquid level sensor?

A float level switch like the 10-787 is a point-level device: a float rides the liquid and actuates a magnetic reed switch at a set height, giving a simple on/off signal — no power, no firmware, no calibration. "Sensors" usually means continuous measurement (ultrasonic, radar, capacitive). ERECTA SWITCH targets reliable discrete-point control.

What factors should I consider when choosing the 10-787?

Consider media chemistry (pick PP, AC, or KR), liquid specific gravity, operating temperature and pressure, mounting style, number of switch points, and electrical contact rating. Compac will spec it from your application — request a free evaluation sample.

What liquid chemistries is the 10-787 compatible with?

Choose the material to match the media: Polypropylene (PP) for general aqueous, acids, and bases; Acetal (AC/Delrin) for solvents, fuels, and hydrocarbons; Kynar PVDF (KR) for aggressive or harsh chemicals. Most ERECTA SWITCH models are offered in all three materials; some are material-specific, so check the product page for the model you need.

What mounting options are available for the 10-787?

ERECTA SWITCH offers vertical top-mount, bulkhead, and extended-stem configurations, plus side-mounted single-point models. The mount style is part of the model number — select the configuration that matches your tank geometry.

How is the actuation level set on the 10-787, and how accurate is it?

Point detection is repeatable and mechanical. The trip height on the 10-787 is set by the 10-715 Precision Nipple, ordered separately in 1-inch increments (1″–70″), so you place the switch point exactly where the application needs it.

What pressure and temperature can the 10-787 handle?

It depends on the series, and the derate matters more than the headline. Series 10 is rated 100 PSI, Series 15 50 PSI and Series 20 20 PSI — each at 20°C, each derating to zero at 90°C, so a hot line has no pressure allowance left. Series 20 sits lowest by design: its float sections are thin-walled, and sustained pressure can crush them. Temperature follows the material — on Series 10, PP: 180°F, AC: 200°F, KR: 280°F.

Can one 10-787 switch control both a high and a low level?

A single switch detects one point. For high-plus-low detection (or more), use a multi-level extended-stem set that places multiple reed points on one stem, giving you independent high and low signals from a single mounting hole.

How do I wire the 10-787 to a pump or alarm?

The 10-787 uses a magnetic reed switch wired in series with your relay or controller. Contact rating is 70 VA / 50 W resistive (UL File E70063). The switch ships with lead wires — connect directly to your control circuit.

Does the 10-787 need calibration?

No. The 10-787 is a mechanical float actuating a sealed reed switch — there is nothing to calibrate or power. This is a reliability advantage over electronic sensors that can drift over time.

How do I maintain the 10-787, and what if it stops working?

Inspect that the float moves freely (check for debris or scaling), then test reed continuity with a multimeter. Because ERECTA SWITCH is modular, you replace only the individual component — switch, float, connector, or fitting — instead of the whole assembly.

Is the 10-787 safe for flammable or hazardous-area liquids?

Standard ERECTA SWITCH models are not rated for hazardous (Class I / Div) areas. For flammable-service applications, contact Compac engineering to discuss your requirements and available options.

What are the typical applications for the 10-787?

The 10-787 is used for pump start/stop control, high-level overflow protection, low-level dry-run protection, and tank or reservoir level alarms in OEM equipment. The modular ERECTA SWITCH system is built into laundry, HVAC, water-treatment, hydraulic, and chemical-handling machinery.

What makes ERECTA SWITCH different from other switches?

It is the only fully modular, off-the-shelf liquid level switch system: switch, float, connector, fitting, and nipple are independently field-replaceable and stocked. OEMs configure exactly what they need with no minimums and short lead times. Made in Paradise, California; RoHS compliant.